Product Details:
Current30 Amps. At 250 V AC for A/C Contacts
TypeMICROPROCEESER
BrandPROTON
Mounting TypePanel Mount
Country of OriginMade in India
  • For Acc-05-09 (1P) Single Phase

  • Supply Voltage: 230 V AC, 50 Hz ??? 15% separate for each A/C.
  • Power Contact Rating: 30 A at 230 V AC for Compressor Outputs Alarm Contact rating 5 A at 250 V AC for Alarm Potential Free Outputs(C, N ,O).
  • Temperature Sensor: Thermistor Sensor NTC 10K@25???C Metal body with clamp. Sensor Cable Length: 2.75 meters.
  • Temperature Sensing Range:0.0???C to 55.0 ???C
  • Resolution: 1V for Voltage, 0.1 A for Current & 0.1???C for Temperature.
  • Auto/ Controller Bypass Switch: To bypass the controller i.e. A/C1 & A/C2 will remain ON continuously if both the switches are in ON Condition
  • Indications: 
    1] Supply ON for A/C1 & A/C2. Colour: Yellow
    2] Auto mode for A/C1 & A/C2 Colour: Green.
    3] Manual Mode for A/C1 & A/C2 Colour: Red.
    4] A/C ON for A/C1 & A/C2 Colour: Green.
    5] Fault for A/C1 & A/C2 Colour: Red.
    6] Room Temperature High: Colour: Red.
    7] Healthy: Colour: Green.
  • For Acc-10-02 (3P) Three Phase

  • Technical Specifications:
    1] Supply Voltage : 3 Phase 415 V AC, 50 Hz +/- 15% separate for each A/C.
    2] Contact Rating: 9 A, 3 Phase contactor for Compressor Live Outputs
        and 5 A at 250 V AC for Alarm Potential Free Outputs (C,N/O)
    3] Temperature Sensor: Thermistor Sensor NTC 10K@25 C Metal body with clamp.
       Sensor Cable Length: 2.75 meters
    4] Temperature Sensing Range: 0.0 C to 55.0 C
    5] Resolution : 1V for Voltage, 0.1 A for Current & 0.1 C for temperature.
    6]Auto/Controller Bypass Switch: To bypass the controller i.e. A/C1 & A/C2 will
        remain ON continuously if both the switches are in ON condition.
    7] Indications: 
       a] Supply ON for A/C1 & A/C2. Colour: Yellow
       b] Auto Mode for A/C1 & A/C2 Colour: Green
       c] Manual Mode for A/C1 & A/C2 Colour: Red
       d] AC ON for A/C1 & A/C2 Colour: Green
       e] Fault for for A/C1 & A/C2 Colour: Red
       f] Room High Colour: Red
       g] Healthy Colour: Green
    8] Keys: 4 key keypad for settings.
       a] SET Key : To enter into SET Mode/To view the next set point
       b] Up Arrow Key : To increment the set point/To view next menu/To view next setpoint in VEW menu.
       c] Down Arrow Key: To decrement the set point/To view previous menu/To view previous set point in VEW menu.
       d] ENTER Key: To come out of SET mode/To enter into menu/To accept the password
    9] Mounting : Flush mounting


Additional Information:

  • Production Capacity: 5 NOS PER WEEK
  • Delivery Time: 1 WEEK
Get Best QuoteRequest A Callback
2 AC Controller With LCD Dispay.
  • 2 AC Controller With LCD Dispay.
  • 2 AC Controller With LCD Dispay.
  • 2 AC Controller With LCD Dispay.
  • 2 AC Controller With LCD Dispay.

2 AC Controller With LCD Dispay.

Product Price: Rs 7,000 / PieceGet Best Price

Minimum Order Quantity: 5 Piece

Product Brochure

Product Details:
PhaseTriple Phase
Current30 Amps. At 250 V AC for A/C Contacts
TypeMICROPROCEESER
BrandPROTON
Mounting TypeWall Mount
  • Modbus Compatibility with BMS over RS-485 Electrical Standard
  • Supply: Single phase 230 VAC, 50 Hz.
  • Display: 16 X 2 LCD Display for Status & Faults.
  • Output: 30 Amps. At 250 V AC for A/C Contacts,
  • Alarm O/P: 2 Nos. Alarm contacts @ 7A 250V AC
  • Sensor: NTC Temp. Sensor for room temp (Range 0 - 55???C)
  • Fire Alarm: Fire Alarm input from Fire Panel
  • Indications: 
    1) Healthy indication for controller.
    2) A/C ON indication for each A/C.
    3) Alarm indication 2 no’s: AC Alarm, Fire Alarm. 
  • Dimensions: 330 (W) X 220 (H) X 80 (D)
  • Front Panel:
    1) 16 X 2 LCD display with backlight.
    2) Key keypad for programming.
    3) A/C1 ON indication.
    4) A/C2 ON indication.
    5) Healthy Indication by blinking Green LED.
    6) ALARM indication by Red LED.
    7) FUN,INC,DEC,ENT keys for parameter setting.
  • Sensing:
    1) Inbuilt Voltage sensing for compressor.
    2) Temperature sensing by Accurate Temp. Sensor
    3) Fire Alarm sensing.
  • Terminals :
    1) Separate O/Ps for each Compressor.
    2) Temperature sensor.
    3) Alarm relay o/p.
  • Alarms/ Protections: 
    1) Over Voltage protection set point user settable.
    2) Under Voltage protection set point user settable.
    3) High/low temperature alarm set point user settable.


  • Additional Information:

    • Production Capacity: 25 NOS PER WEEK
    • Delivery Time: 1 WEEK
    Get Best QuoteRequest A Callback
    Dual AC Controller
    • Dual AC Controller
    • Dual AC Controller

    Dual AC Controller

    Product Price: Rs 8,000 / UnitGet Best Price

    Minimum Order Quantity: 5 Unit

    Product Brochure

    Product Details:
    Model No.DAC-1
    Current30 Amps. At 250 V AC for A/C Contacts
    PhaseSingle Phase
    Voltage220V AC
    Usage/Application2AC AC CONTROL
    BrandPROTON
    Mounting TypeWall Mount
  • Supply Voltage: 230V AC, 50 Hz +/- 15% separate for each A/C.
  • Contact rating: 30 A at 230 V AC for compressor Live Outputs & 5 A at 250 V AC Alarm Potential free outputs(C, N/O)
  • Temperature Sensor: Thermistor sensor NTC 10K @ 25 ???C metal body with clamp. Sensor cable length 2.75 meters.
  • Temperature Sensing Range: 0 - 55???C
  • Resolution: 1 V for voltage, 0.1 A for Current & 0.1 degree C for Temperature.
  • Auto/Controller Bypass Switch is used to bypass the controller i.e. A/C 1 & A/C 2 will remains ON(irrespective of temperature demands) if both switches are in ON condition.
  • Indications :
    a) Supply ON for A/C 1 & A/C 2: Colour: Yellow
    b) Auto Mode for A/C 1 & A/C 2: Colour: Green
    c) Manual Mode for A/C 1 & A/C 2: Colour: Red
    d) A/C 1 & A/C 2 ON: Colour: Green
    e) A/C 1 & A/C 2 Fault: Colour: Red
    f) Room High: Colour: Red
    g) Healthy: Colour: Green
  • Mounting :Wall Mounting


  • Additional Information:

    • Production Capacity: 25 UNITS PER WEEK
    • Delivery Time: 1 WEEK
    Get Best QuoteRequest A Callback
    AC Power Monitor-3P ACPM

    AC Power Monitor-3P ACPM

    Product Price: Rs 4,500 / PieceGet Best Price

    Minimum Order Quantity: 1 Piece

    Product Brochure

    Product Details:
    Model Name/Number3P ACPM
    Usage/ApplicationANY
    Phase3 PHASE
    Application TypeINDUSTRIAL
    Display TypeLCD TYPE
    BrandPROTON
    UsageIndustrial
    • ominal Voltage Input :
      1] Standard Voltage offered 415 V 3Ph AC(R,Y,B,N) Power supply 2] Accuracy Range: 50 – 115 % of nominal voltage.
      3] Burden : < 2.5 VA per phase.
      4] Overload: 1.2x nominal continuous
    • Nominal Input Current : 5 Amp
      1] Accuracy Range for 5 Amps = 120 % nominal.
      2] Burden < 0.5 VA per phase.
      3] Overload 4.0x nominal continuous
      4] Starting current 0.2% of nominal current.
    • Frequency :50 Hz / 60 Hz range (±5 Hz)
    • Measured Parameters :
      1] RMS Voltage (Volt) (R, Y, B Phase) Phase – Neutral measured.
      2] RMS Current (Amps) (R, Y, B Phase) Phase current
      3] Frequency (R, Y, B Phase)
      4] Power Factor (R, Y, B Phase)
      5] Active Power (KVA) (R, Y, B Phase)
      6] Apparent Power (KW) (R, Y, B Phase)
      7] Main’s KWH
      8] DG KWH
      9] DG Run hour
      10] Mains Run hour
    • Protection:
      1] Over Voltage Protection (Settable)
      2] Under Voltage Protection (Settable)
      3] Over Load Protection (Settable)
      4] Under Load Protection (Settable)
      5] Unbalance voltage/current (Settable)
      6] Over Frequency (settable)
      7] Over Frequency (settable)
      8] Total KW Protection. (Settable)
      9] Phase failure protection. (Settable)
    • Auxiliary Power: No External power is required (Draws power from the voltage signal Inputs)
    • Accuracy:
      1] Volt 0.25% ± 1 dgts.
      2] Current 0.25% ± 1 dgts.
      3] Frequency 0.1% Hz ± 1 dgts.
      4] Power Factor 0.25% ± 1 dgts. (for 0.5 Lag – 1.0 - 0.8 Lead)
      5] Active Power 0.5% ± 1 dgts.
      6] Apparent Power 0.25% ± 1 dgts.
      7] Active Energy Class 1.0
    • Communication Output :
      1] Serial port : RS 485
      2] Baud rate : Selectable 1200, 2400, 4800, 9600, 19200. (Default: 9600)
      3] Unit No : 1-32 (Default 1)
      4] Start bit : 1
      5] Stop bit : 1
      6] Protocol : MODBUS - RTU
    • Environmental :
      1] Working Temp : 0 to 55º C
      2] Storage Temp : 10 to 70º C
      3] Relative humidity : 0 – 95 % non-condensive
      4] Warm up time : 30 Sec
    • Enclosure :
      1] Mounting : Panel mounting.
      2] Position : Panel.
      3] Enclosure : 96 X 96 X 110 mm.
      4] Terminal : Screw ON Terminals.


    Additional Information:

    • Production Capacity: 20 NOS PER WEEK
    • Delivery Time: 1 WEEK
    Get Best QuoteRequest A Callback