AC Controller
Leading Manufacturer of dual ac controller, ac power monitor-3p acpm, 2 ac controller with lcd dispay. and space maker ac controller from Pune.
Dual AC Controller
Product Price: Rs 8,000 / UnitGet Best Price
Minimum Order Quantity: 5 Unit
Product Brochure
Product Details:
Current | 30 Amps. At 250 V AC for A/C Contacts |
Model No. | DAC-1 |
Phase | Single Phase |
Voltage | 220V AC |
Usage/Application | 2AC AC CONTROL |
Brand | PROTON |
Mounting Type | Wall Mount |
a) Supply ON for A/C 1 & A/C 2: Colour: Yellow
b) Auto Mode for A/C 1 & A/C 2: Colour: Green
c) Manual Mode for A/C 1 & A/C 2: Colour: Red
d) A/C 1 & A/C 2 ON: Colour: Green
e) A/C 1 & A/C 2 Fault: Colour: Red
f) Room High: Colour: Red
g) Healthy: Colour: Green
Additional Information:
- Production Capacity: 25 UNITS PER WEEK
- Delivery Time: 1 WEEK
Get Best QuoteRequest A Callback
AC Power Monitor-3P ACPM
Product Price: Rs 4,500 / PieceGet Best Price
Minimum Order Quantity: 1 Piece
Product Brochure
Product Details:
Model Name/Number | 3P ACPM |
Usage/Application | ANY |
Phase | 3 PHASE |
Application Type | INDUSTRIAL |
Display Type | LCD TYPE |
Brand | PROTON |
Usage | Industrial |
- ominal Voltage Input :
1] Standard Voltage offered 415 V 3Ph AC(R,Y,B,N) Power supply 2] Accuracy Range: 50 – 115 % of nominal voltage.
3] Burden : < 2.5 VA per phase.
4] Overload: 1.2x nominal continuous - Nominal Input Current : 5 Amp
1] Accuracy Range for 5 Amps = 120 % nominal.
2] Burden < 0.5 VA per phase.
3] Overload 4.0x nominal continuous
4] Starting current 0.2% of nominal current. - Frequency :50 Hz / 60 Hz range (±5 Hz)
- Measured Parameters :
1] RMS Voltage (Volt) (R, Y, B Phase) Phase – Neutral measured.
2] RMS Current (Amps) (R, Y, B Phase) Phase current
3] Frequency (R, Y, B Phase)
4] Power Factor (R, Y, B Phase)
5] Active Power (KVA) (R, Y, B Phase)
6] Apparent Power (KW) (R, Y, B Phase)
7] Main’s KWH
8] DG KWH
9] DG Run hour
10] Mains Run hour - Protection:
1] Over Voltage Protection (Settable)
2] Under Voltage Protection (Settable)
3] Over Load Protection (Settable)
4] Under Load Protection (Settable)
5] Unbalance voltage/current (Settable)
6] Over Frequency (settable)
7] Over Frequency (settable)
8] Total KW Protection. (Settable)
9] Phase failure protection. (Settable) - Auxiliary Power: No External power is required (Draws power from the voltage signal Inputs)
- Accuracy:
1] Volt 0.25% ± 1 dgts.
2] Current 0.25% ± 1 dgts.
3] Frequency 0.1% Hz ± 1 dgts.
4] Power Factor 0.25% ± 1 dgts. (for 0.5 Lag – 1.0 - 0.8 Lead)
5] Active Power 0.5% ± 1 dgts.
6] Apparent Power 0.25% ± 1 dgts.
7] Active Energy Class 1.0 - Communication Output :
1] Serial port : RS 485
2] Baud rate : Selectable 1200, 2400, 4800, 9600, 19200. (Default: 9600)
3] Unit No : 1-32 (Default 1)
4] Start bit : 1
5] Stop bit : 1
6] Protocol : MODBUS - RTU - Environmental :
1] Working Temp : 0 to 55º C
2] Storage Temp : 10 to 70º C
3] Relative humidity : 0 – 95 % non-condensive
4] Warm up time : 30 Sec - Enclosure :
1] Mounting : Panel mounting.
2] Position : Panel.
3] Enclosure : 96 X 96 X 110 mm.
4] Terminal : Screw ON Terminals.
Additional Information:
- Production Capacity: 20 NOS PER WEEK
- Delivery Time: 1 WEEK
Get Best QuoteRequest A Callback
2 AC Controller With LCD Dispay.
Product Price: Rs 7,000 / PieceGet Best Price
Minimum Order Quantity: 5 Piece
Product Details:
Type | MICROPROCEESER |
Current | 30 Amps. At 250 V AC for A/C Contacts |
Brand | PROTON |
1) Healthy indication for controller.
2) A/C ON indication for each A/C.
3) Alarm indication 2 no’s: AC Alarm, Fire Alarm.
1) 16 X 2 LCD display with backlight.
2) Key keypad for programming.
3) A/C1 ON indication.
4) A/C2 ON indication.
5) Healthy Indication by blinking Green LED.
6) ALARM indication by Red LED.
7) FUN,INC,DEC,ENT keys for parameter setting.
1) Inbuilt Voltage sensing for compressor.
2) Temperature sensing by Accurate Temp. Sensor
3) Fire Alarm sensing.
1) Separate O/Ps for each Compressor.
2) Temperature sensor.
3) Alarm relay o/p.
1) Over Voltage protection set point user settable.
2) Under Voltage protection set point user settable.
3) High/low temperature alarm set point user settable.
Additional Information:
- Production Capacity: 25 NOS PER WEEK
- Delivery Time: 1 WEEK
Get Best QuoteRequest A Callback
Space Maker AC Controller
Product Price: Rs 10,000 / UnitGet Best Price
Minimum Order Quantity: 1 Unit
Product Details:
Type | MICROPROCEESER |
Current | 30 Amps. At 250 V AC for A/C Contacts |
Brand | PROTON |
- For Acc-05-09 (1P) Single Phase
- Supply Voltage: 230 V AC, 50 Hz ??? 15% separate for each A/C.
- Power Contact Rating: 30 A at 230 V AC for Compressor Outputs Alarm Contact rating 5 A at 250 V AC for Alarm Potential Free Outputs(C, N ,O).
- Temperature Sensor: Thermistor Sensor NTC 10K@25???C Metal body with clamp. Sensor Cable Length: 2.75 meters.
- Temperature Sensing Range:0.0???C to 55.0 ???C
- Resolution: 1V for Voltage, 0.1 A for Current & 0.1???C for Temperature.
- Auto/ Controller Bypass Switch: To bypass the controller i.e. A/C1 & A/C2 will remain ON continuously if both the switches are in ON Condition
- Indications:
1] Supply ON for A/C1 & A/C2. Colour: Yellow
2] Auto mode for A/C1 & A/C2 Colour: Green.
3] Manual Mode for A/C1 & A/C2 Colour: Red.
4] A/C ON for A/C1 & A/C2 Colour: Green.
5] Fault for A/C1 & A/C2 Colour: Red.
6] Room Temperature High: Colour: Red.
7] Healthy: Colour: Green.
- For Acc-10-02 (3P) Three Phase
- Technical Specifications:
1] Supply Voltage : 3 Phase 415 V AC, 50 Hz +/- 15% separate for each A/C.
2] Contact Rating: 9 A, 3 Phase contactor for Compressor Live Outputs
and 5 A at 250 V AC for Alarm Potential Free Outputs (C,N/O)
3] Temperature Sensor: Thermistor Sensor NTC 10K@25 C Metal body with clamp.
Sensor Cable Length: 2.75 meters
4] Temperature Sensing Range: 0.0 C to 55.0 C
5] Resolution : 1V for Voltage, 0.1 A for Current & 0.1 C for temperature.
6]Auto/Controller Bypass Switch: To bypass the controller i.e. A/C1 & A/C2 will
remain ON continuously if both the switches are in ON condition.
7] Indications:
a] Supply ON for A/C1 & A/C2. Colour: Yellow
b] Auto Mode for A/C1 & A/C2 Colour: Green
c] Manual Mode for A/C1 & A/C2 Colour: Red
d] AC ON for A/C1 & A/C2 Colour: Green
e] Fault for for A/C1 & A/C2 Colour: Red
f] Room High Colour: Red
g] Healthy Colour: Green
8] Keys: 4 key keypad for settings.
a] SET Key : To enter into SET Mode/To view the next set point
b] Up Arrow Key : To increment the set point/To view next menu/To view next setpoint in VEW menu.
c] Down Arrow Key: To decrement the set point/To view previous menu/To view previous set point in VEW menu.
d] ENTER Key: To come out of SET mode/To enter into menu/To accept the password
9] Mounting : Flush mounting
Additional Information:
- Production Capacity: 5 NOS PER WEEK
- Delivery Time: 1 WEEK
Get Best QuoteRequest A Callback